Product Category

Got any Questions? Call us Today!

+8618758069661

service@fctel.com.cn

Or leave us a message

Online Message

Dry Contact Closure over Fiber Converter (32Ch Unidirectional/16Ch Bidirectional)

View : 954
Type : Dry Contact Closure over Fiber
Description :

This device provides 1-32 channel unidirectional dry contact or 16 channel bidirectional dry contact.

Overview

This device provides 1-32 channel unidirectional dry contact or 16 channel bidirectional dry contact. As a result of the fiber as a transmission medium, you can completely avoid the threat to communication devices under adverse environments, such as lightning, surges, and electromagnetic interference, to improve the reliability, security, and confidentiality of data communication.

 

It can be widely used in various occasions, such as industrial management, process management, and traffic management,  especially for banks, electric power, and some departments who has special requirements for electromagnetic interference environment.

Photo

dry contact closure over fiber converter

Features

● Support point-to-point network topology

● Provide two optical interfaces, 1 + 1 optical interface protection (APS)

● The electric interface is powered by an independent power supply module, which completely isolates the ground circuit between the bus and the equipment. At the same time, the photoelectric isolation technology is used to isolate the internal communication and bus data signals, which effectively protects the communication equipment from the interference of the power supply ground circuit and surge.

● Support 32-channel unidirectional dry contact or 16-channel bidirectional dry contact

● There are indicators on each channel to show on or off of the dry contact

● Automatically detect on and off of-day contact closure, the output is what the input state, with the convenience of the project

● When the dry contact closure on or the optical fiber is not connected, the switch state is stable and there will be no disorderly action

● Input interface self-band filter can filter out interference pulse and ensure stable output signal of the output terminal

● Can set the open and closed states of each channel when the optical fiber is not connected

● Lightning protection can reach IEC61000-4-5 (10/ 700μS)  differential mode: 6KV, impedance (2Ω); Common mode: 6KV, impedance (2Ω) standard

Parameters

● Fiber

Multi-mode Fiber

50/125um, 62.5/125um,

Transmission distance: 2Km  multi-mode fiber, attenuation (3dbm/km)

Wave Length: 820nm

Transmitting power: -12dBm (Min) ~-9dBm (Max)

Receiver sensitivity: -28dBm (Min)

Link budget: 16dBm

Single-mode Fiber

8/125um, 9/125um

Transmission distance: 20Km  single mode fiber, attenuation (0.35dbm/km) (Customization is provided for larger distances)

Wave Length: 1310nm

Transmitting power: -9dBm (Min) ~-5dBm (Max)

Receiver sensitivity: -27dBm (Min)

Link budget: 18dBm

 

● Dry Contact Interface

Respond Time: <0.5ms

Switch Signal: 30VDC/0.5A

The maximum switching frequency: 50HZ

Physical interface: Phoenix terminal

 

● Electrical and Mechanical Features

Power: AC180V ~260V;DC –48V;DC +24V

Power consumption: ≤5W

Dimension: 485*200*45mm  19 inch

 

● Working Environment

Working temperature: -10°C ~ 60°C

Working Humidity: 0%~95 % (no condensation)

Storage temperature: -40°C ~ 85°C

MTBF:  >100,000hours

Specifications

Name

32 channel 19 inch dry contact closure Mux

Functional Description

provides 32-channel unidirectional dry contact or 16-channel bidirectional dry contact closure

Port Description

Two 1*9 optical fiber interface;32 Dry contact closures

Power

AC220V;DC –48V (optional);Support power redundancy backup

Dimension

Product Size: 485X220X45mm  19 inch

Weight

3KG/piece

Application

application of Dry Contact Closure over Fiber Converter

                   

Leave a Message